2) Abnormal Refrigerator Sensor Error (1)
CHECKING FLOW RESULT & SERVICE ACTION
Unplug connector of Control Box.
Unplug connector in CON 7 and check between
White to White as is shown in the picture.
Result
Service Action
0 Ù
OFF
Replace Product
Short
Open
4
5
NO.
6
1) Remove the Control Box in Refrigerator sensor.
Check resistance value between and .
Go to Step 5.
Go to Step 6
1
2
4
3
1
4
Result
Service Action
0 Ù
OFF
Replace Control Box
Assembly or sensor
(if possible).
Other
Short
Open
Normal
Check the Temperature
and Resistance
(Temperature Chart #2)
Go to Step 7
Resistance Values are according to Temperature
Chart table?
Result
Service Action
YES
NO
Replace Main PCB
Replace Sensor
Normal
Sensor
Abnormal
Sensor
7
- 80 -