EasyManua.ls Logo

LG LSC27914SB - Page 93

LG LSC27914SB
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1) Reset product.
2) Remove Cover PCB.
3) Enter to TEST MODE 1 (press once TEST S/W
on Main PCB)
4) Check voltage in CON 6 as shown in the pictures.
Disconnect Motor connector, and check status of
plated terminals.
Terminals contact surface must be free of rust and
dirt. Also, the terminals must be assured with a
T.P.A., Motor wire must not have any damage.
5
NO.
CHECKING FLOW RESULT & SERVICE ACTION
6
Result
Service Action
(a) ~ (b)
(b) ~ (c)
Change Main PCB
Below 10V
0V or 5V
Go to Step 6
Reset the product.
After 3 minutes execute DISPLAY CHECK MODE,
check the result.
Result
Service Action
All Display
LED’s are
turned ON
Freezer Fan
Error Code
appears
Explain to the customer
Normal
Abnormal
Replace Freezer
Fan Motor
7
(a) ~ (b)
(b) ~ (c)
Result
Service Action
Wire damage,rust, dirt,
TPA absences.
Normal appearance
Replace Motor
Go to Step 7
10) Abnormal Freezer Fan Error
- 92 -