Unplug connector from Duct motor and check the
resistance value.
Check Duct Motor signal in CON 9.
5
NO.
CHECKING FLOW RESULT & SERVICE ACTION
6
NOTE: Voltage only will be appreciated during the
first second after press lever S/W after release
lever S/W voltage to close Duct Motor will be applier.
Refer to next diagram.
Result
Service Action
to
Go to Step 6
9.9 ~12.1 Ù
Other
Replace Duct Motor
7
2
3
Lever S/W
Service Action
Pressing
Go to Step 7
+/- 12Vdc
Other
Change PCB
Not
Pressing
Go to Step 7
Same than
pressing
voltage, but
inverted
Other
Change PCB
12) Ice Crush Mode is not working
ITEM STATUS
Pressed
Lever S/W Released
0 1 2 3 4 5 6 7 8 9 10 11 12 13
12V
Duct Motor 0V
-12V
Remove Cover hinge in Freezer Door, and check
connection.
Result
Service Action
Firmly plugged
Loose
Go to Step 8
- 97 -