EasyManua.ls Logo

LG LT-B2461CL - Page 12

LG LT-B2461CL
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
• HEAT PUMP
12
INDOOR UNIT OUTDOOR UNIT
HEAT
EXCHANGER
HEAT
EXCHANGER
COMPRESSOR
GAS SIDE
LIQUID SIDE
COOLING
HEATING
REVERSING
VALVE
CHECK VALVE
CAPILLARY TUBE
CAPILLARY TUBE
Rated performance for refrigerant line length of: 5m
If 24K or 28K Model is installed at a distance of 15m, 500g of refrigerant
should be added ....................................................(15-5)x50g
MODEL
24K, 28K, 30K BTU
5/8" 3/8" 5 20
36
K BTU
3/4" 3/8" 5 25
GAS LIQUID
515 50
520 70
Elevation B(m)
Length A(m)
* Additional
refrigerant
(g/m)
Pipe Size
Rated Rated
Max. Max.

Related product manuals