22
Installation of Indoor, Outdoor Unit
1. Selection of the best location
1) Indoor unit
There should not be any heat source or steam
near the unit.
There should not be any obstacles to prevent the
air circulation.
A place where air circulation in the room will be
good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into con-
sideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall, ceiling, or other obstacles.
The indoor unit must keep the maintenance
space.
2) Outdoor unit
If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat
radiation from the condenser is not restricted.
There should not be any animals or plants which
could be affected by hot air discharged.
Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
More than 10cm
More than 10cm
More than 70cm
Unit:cm
Ceiling
Ceiling Board
Ceiling Board
30 or more
Above 250
300 or less
100
or more
50 or
more
50 or
more
30 or less
Floor