27
5. Wiring Connection
Open the control box cover and connect the Remote control cord and Indoor power wires.
The power cord connected to the outdoor unit
should be complied with the following specifications
(Rubber insulation, type H05RN-F approved by HAR
or SAA).
The connecting cable connected to the indoor and
outdoor unit should be complied with the following
specifications (Rubber insulation, type H05RN-F
approved by HAR or SAA).
CAUTION
8.5mm
20mm
GN/YL
NORMAL CROSS-SECTIONAL AREA
Capacity 1 Phase 3 Phase
36K BTU/h
5.5mm
2
2.5mm
2
24,28,30K
BTU/h
2.5mm
2
-
7.5mm
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
Remote control
cord
Control
box cover
Control box cover
fitting screw (4 units)
[Air inlet side view]
Wire taking inlet
Indoor Power wires
Terminal Block of Indoor Unit
3(N) 4(L)
567 SRT
3(N)
N
4(L)
5678
Terminal Block of Outdoor Unit
Power Cord
Terminal Block of Indoor Unit
3(N) 4(L)
567 SRT
3(N)
N
4(L)
5678
Terminal Block of Outdoor Unit
Power Cord
Terminal Block of Indoor Unit
3(N) 4(L)
567
1(N) 2(L) 3(N) 4(L)
5678
Terminal Block of Outdoor Unit
Power Cord
Terminal Block of Indoor Unit
3(N) 4(L)
567
1(N) 2(L) 3(N) 4(L)
5678
Terminal Block of Outdoor Unit
Power Cord
Make sure that the screws of the terminal are free from looseness.
WARNING
1 Phase
Heat Pump Model
Cooling Model
3 Phase
Heat Pump Model
Cooling Model