[Air inlet side view]
The power cord connected to the outdoor unit should be complied 
with the following specifications (Rubber insulation, type H05RN-F 
approved by HAR or SAA).
The connecting cable connected to the indoor and outdoor unit should 
be complied with the following specifications (Rubber insulation, 
type H05RN-F approved by HAR or SAA).
CAUTION
8.5mm
20mm
GN/YL
7.5mm
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
NORMAL
CROSS-SECTIONAL
AREA 2.5mm
Terminal Block of Indoor Unit
3(L) 4(N)
567
1(L) 2(N) 3(L) 4(N)
5678
Terminal Block of Outdoor Unit
Power Cord
Terminal Block of Indoor Unit
3(L) 4(N)
567
1(L) 2(N) 3(L) 4(N)
5678
Terminal Block of Outdoor Unit
Power Cord
Control box cover
Indoor 
power cord
Remote 
controller
cord
Control box cover 
fitting screw(2 units)
5. Wiring Connection
• Open the control box cover and connect the Remote controller cord and Indoor power wires.
• Heat Pump Model
• Cooling Model
Make sure that the screws of the terminal are free from looseness.
WARNING
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufac-
turer or its service agent.