9
EN
INSTALLATION
Electrical Data
Power cord may include a current interrupter 
device. TEST and RESET buttons are provided 
on the plug case. The device should be tested on 
a periodic basis by frist pressing the  TEST button 
and then the RESET button. If the TEST button 
does not trip or if the RESET button will not stay 
engaged, discontinue use of the air conditioner 
and contact a qualified service technician.
for 115 V
Model
Use Wall 
Receptacle
Power 
Supply
LT0816CER
LT1016CER
LT1216CER
Standard 125 V, 
3-wire grounding 
receptacle rated 
15 A / 125 V AC
Use 15 A, 
time delay 
fuse or     
15 A, circuit 
breaker.
for 230 V
Model
Use Wall 
Receptacle
Power 
Supply
LT1036CER
LT1236CER
Standard 250 V, 
3-wire grounding 
receptacle rated 
15 A / 250 V AC 
Use 15 A, 
time delay 
fuse or     
15 A, circuit 
breaker.
WARNING
 • This appliance should be installed in 
accordance with the National Electrical Code.
 • Use of extension cords could cause serious 
injury or death.
 − Do not use an extension cord with this 
window air conditioner.
 − Do not use surge protectors or multi-outlet 
adapters with this window air conditioner.
 • Never push the TEST button during operation. 
Doing so can damage the plug.
 − Do not remove, modify, or immerse this 
plug. If this device trips, the cause should be 
corrected before further use.
CAUTION
 • The conductors inside this cord are surrounded 
by shields, which monitor leakage current. 
These shields are not grounded. Periodically 
examine the cord for any damage. Do not 
use this product in the event the shields 
become exposed. Avoid shock hazard. This 
unit cannot be user-serviced. Do not open the 
tamperresistant sealed portion. All warranties 
and performance will be voided. This unit is not 
intended to be used as an ON/OFF switch.