- Defrost Sensor Error
4
5
40
Check the voltage between orange wires
(these are connected to PCB) for CON8.
No Checking Result and SVC countermeasure
0 Short
OFF
Open
Other value Normal
1. Check temperature and resistance
(see chart of section 7-2).
2. Go to step 5.
Result SVC Support
Replace the product.
Check the voltage between orange wires
(sensor wires) for CON8.
0V
Out of
Control
Replace (PCB)
5V
Other value
between
0V & 5V
Normal
Result SVC Support
1. Check temperature and resistance
(see chart of section 7-2).
2. Explain to customer about loose
and dirty connectors.