Installation
_To prevent vibration and noise, make sure the unit
is installed securely and firmly
Install the unit where the sunlight does not shine
°
directly on the unit. Cooled air I'-r' "_ Heat \\
_ I radiation .
The outside of the cabinet must extend outward for _=__/_ [ i _
at least 12" and there should be no obstacles, such I
as a fence or wall, within 20" from the back of the - - •
cabinet because it willprevent heat radiation of the ' _
condenser. 0" ,"
Restriction of outside air will greatly reduce the
\\ \\ _\\\
cooling efficiency of the air conditioner.
Fence
_lb AUTION: All side louvers of the cabinet must remain exposed to the outside of thestructure.
Install the unit a little slanted so the back is slightly lower than the front (about 1/2").
This will force condensed water to flow to the outside.
Install the unit with the bottom about 30"-60" above the floor level.
:All supporting parts should be secured to firm wood, masonry, or metal.
• This unit is designed for installation in standard double
hung windows with actual opening widths from 27"
to 39".
• The top and bottom window sash must open sufficiently
to allow a clear vertical opening of 16" from the bottom
of the upper sash to the window stool.
_J"' _iliiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiil
11 27to39__
16" min qt,-,,,
VV,,ou,,,,m c0r' a
Offset
. "_,. V2" to 11/4"
._°°_Exterior
12 Room Air Conditioner