A15
Controlling the Multiple Product
RS-232C
26. Tile ID Set(Command : d i)
To assign the Tile ID for Tiling function .
Transmission
[d][i][][Set ID][][Data][x]
* The data range is from 00 to 00 x 10 tile mode.
Acknowledgement
[i][][Set ID][][OK/NG][Data][x]
27. Elapsed time return(Command : d l)
To read the elapsed time.
Transmission
[d][l][][Set ID][][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[l][][Set ID][][OK/NG][Data][x]
* 28. Light Sensor value Return(Command : d m) - Optional
To read the light sensor value for adjusting the
product
brightness
depending on the surrounding brightness .
Transmission
[d][m][][Set ID][][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[m][][Set ID][][OK/NG][Data][x]