ELECTRICAL WIRING
65
ENGLISH
MODE FUNCTION OPTION VALUE ACTION
REMARK
Content
Display1
Content
Display2
Content Display3
Content
Display4
Implement Display5
Installation
Cool & Heat
Selector
oFF
op1~op2
selected the
option
- -
change the
set value
blank
save in
EEPROM
Static pressure
compensation
oFF
op1~op3
selected the
option
- -
change the
set value
blank
save in
EEPROM
Night low noise
oFF
op1~op15
selected the
option
- -
change the
set value
blank
save in
EEPROM
ODU address
-
-
0~254
set the
value
change the
set value
blank
save in
EEPROM
Snow removal &
rapid defrost
oFF
op1~op3
selected the
option
- -
change the
set value
blank
save in
EEPROM
Target pressure
adjusting
oFF
op1~op6
selected the
option
- -
change the
set value
blank
save in
EEPROM
* Functions save in EEPROM will be kept continuously, though the system power was reset.
* DIP switch 3 can be OFF except when installing the only 4 series indoor units
(named ARNU***4).
Setting the function
Select the mode/function/option/value using ‘’, ‘’ Button and confirm that using the ‘
button after DIP switch No.5 is turned on.
DIP SWITCH 7-Segment
DIP SWITCH
7-Segment
SW01C (Ɨ : confirm)
SW01C (Ɨ : confirm)
SW02C (ȭ : backward)
SW02C (ȭ : backward)
SW04C ( X : cancel)
SW04C ( X : cancel)
SW01D (reset)
SW01D (reset)
SW03C ( ȯ: forward)
SW03C ( ȯ: forward)
(U4)(U3 / U7)