31
206-4350
EZ-Manager Wizard (Cont.)
(Continued from previous page)
3. Refer to the appropriate subsection below, depending on the Pro:Centric server conguration, to
complete the remaining elds.
RF Conguration
a) In the Media Type eld, use the Left/Right arrow keys to select RF.
b) In the Data Channel eld, use the Left/Right arrow keys to select the RF channel number
that will be used by the Pro:Centric server as its data channel. The Data Channel value can
be set from 1 to 135.*
IP Conguration
a) In the Media Type eld, use the Left/Right arrow keys to select IP.
Note: When you select “IP” as the Media Type, the default RF Data Channel and Signal
Strength/Quality elds are replaced with Server Address, IP Type, IP Address, and IP Port
elds.
b) The Server Address eld provides the option to specify the domain name of the Pro:Centric
server instead of the server’s IP address. Use the Left/Right arrow keys to select the desired
option—IP Address or Domain Name—for dening the server.
c) Depending on your selection in the previous step, either:
Select the appropriate IP type (either IPv4 or IPv6) in the IP Type eld, and then enter the
Pro:Centric server IP address in the IP Address eld. The IP address must match the IPv4
or IPv6 (as applicable) address that is set in the Pro:Centric server.
Enter the Pro:Centric server domain name in the Domain Name eld. Note that in order
for the domain name to be resolved to an IP address, there must be a DNS entry for the
domain name.
For each data entry eld: Use the arrow keys on the Installer Remote to select the eld and
press the Wheel (OK) button. Then, you can either use the number keys to direct enter data
values, or you can use the arrow keys to select the appropriate number(s)/alphanumeric
character(s) from the pop-up virtual keyboard displayed at the bottom of the screen. When
you are done, select Enter from the virtual keyboard, and then press the Wheel (OK) button.
Note: For an IPv6 IP address, you must use the colon “:” key from the virtual keyboard to
separate each group
d) Enter the Pro:Centric server port number in the IP Port eld. The port number must match the
port number that is set in the Pro:Centric server.
4. Once all elds are completed as required, you have two options:
To save the data entered and exit the wizard, use the arrow keys to select the
X
button at the
top right of the screen, and then press the Wheel (OK) button. In the subsequent pop-up
conrmation window, select SAVE & EXIT, and then press the Wheel (OK) button once more.
The Pro:Centric application and/or E-Z Installation data will be downloaded to the TV at a later
time. This option is useful, in particular, if the Pro:Centric server has not yet been congured.
* PCS150R and later Pro:Centric servers do not support HRC or IRC cable channel frequencies.
(Continued on next page)