12
y For closet installation, with a door,
minimum ventilation openings in the
top and bottom of the door are required.
Louvered doors with equivalent ventilation
openings are acceptable.
Closet Ventilation Requirements
Closets with doors must have both an upper
and lower vent to prevent heat and moisture
buildup in the closet. One upper vent opening
with a minimum opening of 48 sq. in. (310 cm
2
)
must be installed no lower than 6 feet above the
floor. One lower vent opening with a minimum
opening of 24 sq. in. (155 cm
2
) must be installed
no more than one foot above the floor. One
example shown uses vent grilles in the door.
Installation Spacing for Recessed Area or Closet Installation
There should be at least a little space around the Styler (or any other appliance) to avoid contact with
walls, furniture, or other appliances during operation. Allow a minimum of 1
3
/
16
inch (3 cm) on all sides
of the Styler to avoid increased noise or damage.
48 sq. in.
(310 sq. cm)
24 sq. in.
(155 sq. cm)
3"
(7.6 cm)
3"
(7.6 cm)
Vent
Vent
in.
in.
closet door vent
requirements
7 3/4 in.
(20 cm)
2 in.
(5 cm)
2 in.
(5 cm)
18 in. (46 cm)
in front
25 ½ in.
(650mm)
18 in. (455mm)
10 in. (250mm)
Built-In Installation
Wall
Wall
2 in. (50 mm)
1
3
/16 in. (30 mm)
1 in. (25 mm)
1
3
/16 in. (30 mm)
Wall
Ceiling
The following clearances are recommended for
the Styler. Although the Styler has been tested
for clearances of 1
3
/
16
inch (3 cm) on the sides
and rear, recommended clearances should be
considered for the following reasons:
y Additional space should be considered for
ease of installation and servicing.
y Additional space might be required for
wall, door and floor moldings.
y Additional space should be considered
on all sides of the Styler to reduce noise
transfer.
y Additional laundry appliance spacing
should also be considered.
y Minimum vent opening for built-in
installation is 31 ½ sq. in. (200 cm
2
).
74.4 in. (1,
890 mm)
19 in. (485 mm)
24.8 in. (630 mm)
73.8 in. (1,875 mm)
18 in. (455 mm)
1850mm
445mm
585mm
15.75 in. (400 mm)
2 in. (50 mm)