Accessories Installation
Installation Manual 63
ENGLISH
ʶ
ʹ
ʸ
ʶ
ʺ
Terminal
Block 3
Terminal
Block 1
ʸ
ʶ
ʶ
ʷ
ʹ
ʺ
Terminal
Block 1
Terminal
Block 3
Relay contactor
port no. assignment
ELB(MCCB) port no.
assignment
1 3
2 4
How to Install Sanitary Water Tank Kit
Fellow bellow procedures Spet 1 ~ Step 5
Step 1. Find magnetic switch and ELB(MCCB) in the kit. Fit
them into the indoor unit control box with enclosed a
braket and screws.(symbol
at picture)
Step 2. Contact ‘CN_B/HEAT(A)’(white connector)of the indoor
unit PCB with magnetic switch contact using encolsed
cable(symbol
at the picture). Connect magnetic
switch contactor port no. A1 and A2.
Step 3. Connect magnetic switch contactor port no.L1 and L3
with RLB(MCCB) port no. 2 and 4(symbol
at the pic-
ture).
Check Poarity
• Connect magnetic switch contact port no. L1 to ELB(MCCB)
port no.2
• Connect magnetic switch contact port no. L3 to ELB(MCCB)
port no.4
Step 4. Connect magnetic switch contactor port no. T1 and T3
with terminal block 1 port 6 and 7(symbol at the pic-
ture).
Check Polarity
• Connect magnetic switch contact port no. T1 to terminal
block 1 port 6
• Connect magnetic switch contact port no. T3 to terminal
block 1 port 7
Step 5. 1Ø Electric Heater
Connect ELB(MCCB) port no.1 and 3 with block 3
port 3 and 4(symbol
at the picture).
Connect ELB(MCCB) port no.1 and 3 with block 3
port 1 and 2(symbol
at the picture).
Check Polarity
- Connect ELB port no. 1 to terminal block 3 port 3
- Connect ELB port no. 3 to terminal block 3 port 4
- Connect MCCB port no. 1 to terminal block 3 port 1
- Connect MCCB port no. 3 to terminal block 3 port 2
CAUTION
Note:
Some models are using MCCB instead of ELB
3ø Electric Heater