Page #57 background image
56 2005 Product Data
6. Wiring Diagrams Outdoor Units
Single Split H/P (18~24k Btu.)
COMP
C
S
R
FAN
MOTOR
BR
BR
BL
RD
BK
GN/YL
BR
BL
RD
YL
RD
BK(RD)
BK
(RD)
BL
GN/YL
REVERSING
RD
CAPACITOR
BL
TO INDOOR UNIT
3854A20123J
TERMINAL
BLOCK
HCF
PTC
1
(
L
)
2
(
N
)
34
VALVE
T / B 2
T / B 1
WIRING DIAGRAM
COMP
C
S
R
FAN
MOTOR
BR
BR
BL
RD
BK
GN/YL
BR
BL
RD
BK
YL
BK(RD)
BK
(RD)
BR(OR)
GN/YL
REVERSING
YL
CAPACITOR
RD
TO INDOOR UNIT
3854A20167A
TERMINAL
BLOCK
HCF
PTC
1
(
L
)
2
(
N
)
34
VALVE
T / B 2
T / B 1
WIRING DIAGRAM