19
7-3. HOW TO CHECK THE WATER LEVEL FREQUENCY
7-4. HOW TO KNOW TO TEMPERATURE OF EACH THERMISTOR
AT OPERATING CONDITION.
The digits means water level frequency. (10
-1
kHz)
ex) 241 : Water level frequency = 241 x 10
-1
kHz
24.1 kHz
Press the Intensive and Option(Left) button simultaneously.
Press the Temp. and Option(Left) button simultaneously.
Thermistor in tub temperature.