24
Is the Connector connected correctly to
the Main PCB and the Pump Motor ?
Or is the Harness alright ?
Is the Standpipe Height greater
than 1.0 m above the floor?
When there is not water in the
pump casing, is the water level
frequency over 26.2KHz ?
Observe Standpipe Height requirements
of 1.0m maximum.
- Your washer will not be able to drain out
water adequately, if the standpipe exceeds 1.0 m.
In this case, water may flow back into the washer.
Check the Air Chamber and the Tube (clogged).
And When you check the water level frequency
again, if it is over 25.5KHz, you replace the
Pressure switch.
YES
NO
Reconnect or repair the Connector.
Or replace the Harness.
NO
Replace the Main PCB.
NO
Replace the Pump Motor.
Is the resistance of the Pump Motor out
of 152 ~ 175Ω?
Or is the Impeller operating normally?
Is Pump motor started, when the spin mode is
started ?
Escape Binding
NO
NO
YES
YES
OR
YES