19
ESUACMOTPMYSRORRE
LOCKED MOTOR
ERROR
EEPROM ERROR
• The connector (3-pin, male, white) in the MOTOR
HARNESS is not connected to the connector (3-pin,
female, white) of STATOR ASSEMBLY.
• The electric contact between the connectors (3-pin,
male, white) in the MOTOR HARNESS and 4-pin,
female, white connector in the MAIN PWB
ASSEMBLY is bad or unstable.
• The MOTOR HARNESS between the STATOR
ASSEMBLY and MAIN PWB ASSEMBLY is cut
(open circuited).
•
8
• EEPROM is out of order.
Displayed only when the START/PAUSE button is
first pressed in the Load Test Mode.
9
gnihsaw elihw deppots si ylppus rewop eht retfA•ERULIAF REWOP
machine is working, the power is supplied rapidly.