EasyManua.ls Logo

LG WT-R107 - Page 41

LG WT-R107
55 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41
ERROR
OVER
FLOODING
ERROR
PRESSURE
SENSOR
MOTOR
ERROR
Water Pressure
Switch is off.
1. Check blockage in air hole of
outer tub or pressure air tube.
2. Check air leakage at the air
hole of outer tub or pressure air
tube.
1.Connector to the PRESSURE S/W
ASM or RED 4 pin connector to
P.W.B ASM has bad connection.
2.PRESSURE S/W is bad. (In the
initial state of QC TEST MODE,
the number on the DISPLAY is
less than 60 or more than 104)
1. Connector the HALL Sensor or
Blue 4 Pin connector to P.W.B
ASM had bad connection.
2. Connector the stator ASM, and
YELLOW 3 Pin or Natural 6 Pin
connector to P.W.B ASM had
bad connection
3. Hall sensor is bad.
4. Locked by Bearing Housing
1. Remove the foreign objects in
there.
2. Replace or Repair the outer tub.
Replace the Pressure sensor
switch.
1. Correct the connector contact.
2. Replace PRESSURE S/W
ASM.
1. Correct the connect contact.
2. Correct the connect contact.
3. Replace the Stator ASM.
4. Replace the Bearing
Housing ASM. Otherwise
Replace P.W.B ASM.
ERROR DECISION
BASIS
CAUSE FOR ERROR
OCCURRENCE
REMEDY
CLUTCHING
ERROR
1. Connector to the Clutch Motor or
BLUE 3 Pin connector to P.W.B
ASM had bad connection.
2. Bad Clutch Motor.
1. Correct the connect contact.
2. Replace the Clutch Motor.
COUPLING
ERROR
Check whether the coupling of
Bearing Housing ASM has
broken.
1. Replace the Bearing
Housing ASM or Coupling
ASM.
BRAKE
RESISTER
ERROR
1. Connector to the Break Resistor
or GRAY 2 Pin connector to
P.W.B ASM had bad connection
2. Check whether the Brake
Resistor has broken
3. Check whether P.W.B ASM has
broken
1. Corret the connect contact
2. Change the Brake Resistor
3. Change P.W.B ASM