EasyManua.ls Logo

LI-COR li-6262 User Manual

LI-COR li-6262
127 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
LI-6262
CO
2
/H
2
O Analyzer
®
INSTRUCTION MANUAL
Question and Answer IconNeed help?

Do you have a question about the LI-COR li-6262 and is the answer not in the manual?

LI-COR li-6262 Specifications

General IconGeneral
BrandLI-COR
Modelli-6262
CategoryMeasuring Instruments
LanguageEnglish

Summary

Federal Communications Commission Radio Frequency Interference Statement

NOTICE

Printing History

Details the revisions and print dates of the manual.

Unpacking and Inspection

What's What

Identifies all items included with the LI-6262 upon delivery.

Checking the Batteries

Procedure for verifying battery charge status upon receipt.

Setup and Operation

Initial Setup Procedures

Guides through installing filters, preparing tubes, and initial configuration.

Powering On the Analyzer

Details the procedure for turning on the LI-6262 and expected indicators.

Gelman Filter Installation

Instructions for installing external air filters to prevent contamination.

Absolute vs. Differential Mode Operation

Explains the differences and setup for absolute and differential modes.

Theory of Operation

General Description of the Analyzer

Overview of the LI-6262 as a differential NDIR gas analyzer.

Calculating Gas Concentration - General Principles

Explains how detector output relates to gas concentration using detector signals.

Calculating CO2 Concentration

Details the formulas and functions for determining CO2 concentration.

Calculating H2O Concentration

Details the formulas and functions for determining H2O concentration.

Pressure Broadening Effects

Explains how pressure affects infrared detection and absorption bands.

Dilution Corrections

Describes how to correct CO2 readings for differences in water vapor.

Handling Unknown Reference CO2

Methods for measuring CO2 differential when reference CO2 is not precisely known.

Calibration

Calibration - General Information

Overview of factory and user calibration procedures for CO2 and H2O.

Differential Mode Calibration Procedures

Step-by-step guide for zero and span calibration in differential mode.

Absolute Mode Calibration

Procedure for zero and span calibration in absolute mode.

H2O Absolute Mode Cautions

Specific warnings and recommendations for H2O measurements in absolute mode.

Pressure Corrections

Method for characterizing and accounting for pressure effects on span.

Software Zero and Span Adjustment

Using software functions for zero and span adjustments instead of potentiometers.

Using the LI-670 Flow Control Unit

Guide on calibrating the LI-6262 using the LI-670 unit.

System Software

Using the Keypad Interface

Explains the functions of each key on the LI-6262 keypad.

Software Overview and Navigation

Describes how software commands are executed and menus are navigated.

Console Commands Reference

Details specific functions and commands for system operation and configuration.

Interfacing

Interfacing General Information

Describes the three methods for obtaining data: display, RS-232C, and analog output.

RS-232C Data Output

Details RS-232C communication parameters and capabilities.

Analog Output Channels

Explains the linear voltage and current analog output channels.

RS-232C Data Transfer and Cable Selection

Guidance on selecting appropriate cables for RS-232C data transfer.

RS-232C Software Configuration

Steps to configure the LI-6262 for RS-232C data transmission.

Sending Remote Commands

Instructions for sending commands to the LI-6262 via computer or terminal.

Uploading ASCII Configuration Files

Method for sending command files to configure the LI-6262.

Analog Output Configuration

Configuring DAC channels for scaled analog voltage or current outputs.

Auxiliary Channel Inputs

Connecting external sensors to the auxiliary input channel.

Analyzer Temperature Output

Connecting a logger to measure analyzer temperature.

Using the 6262-03 Pressure Transducer

Installing and configuring the pressure transducer for automatic corrections.

Maintenance

Battery Recharging and Storage

Instructions for charging and storing LI-6262 rechargeable batteries.

Opening the LI-6262 Housing

Procedure for safely opening the instrument case for servicing.

Internal Soda Lime/Desiccant Replacement

Guidance on replacing the internal desiccant for optimal performance.

External Soda Lime/Desiccant Maintenance

Frequency and procedure for replacing external soda lime/desiccant tubes.

Fan Filter Cleaning and Replacement

Instructions for cleaning or replacing the external fan filter.

Fuse Identification and Replacement

Locating and identifying fuses for power supply issues.

Troubleshooting

Power On Issues

Addresses issues like no power or flickering display during startup.

Ready Light Not Illuminating

Diagnoses reasons why the READY light may not turn on.

Zero and Span Adjustment Difficulties

Troubleshooting tips for setting zero and span potentiometers.

Over-Range Display Errors

Interprets displays showing CO2, H2O, or AUX instead of numerical values.

Zero Readings for CO2/H2O

Checks calibration and pressure settings when zero values are displayed.

Specifications

H2O Analyzer Specifications

Detailed specifications for H2O range, accuracy, drift, and noise levels.

CO2 Analyzer Specifications

Detailed specifications for CO2 range, accuracy, drift, and noise levels.

6262-03 Pressure Transducer Specifications

Specifications for the pressure transducer, including range, accuracy, and noise.

Suppliers

Soda Lime and Magnesium Perchlorate Suppliers

Lists suppliers for soda lime and magnesium perchlorate chemicals.

Software Commands

Setup Commands Overview

Lists and describes commands for initial setup and configuration.

Channel Codes Reference

Provides a list of channel codes for CO2, H2O, and Miscellaneous data.

Channel Code Headers

CO2 Channel Code Headers

Headers for various CO2 data channels transmitted via RS-232C.

H2O Channel Code Headers

Headers for various H2O data channels transmitted via RS-232C.

Miscellaneous Channel Code Headers

Headers for temperature, pressure, and auxiliary data channels.

Console Commands

Console Setup Commands

Lists and describes commands for initial setup and configuration.

Console Channel Codes Reference

Provides a list of channel codes for CO2, H2O, and Miscellaneous data.

CO2 and H2O Calibration Stacks

Miscellaneous, DAC, and Display Stacks

Remote Commands Reference

Connector Descriptions

25-Pin RS-232C DCE Port Pinout

Details the pin assignments for the RS-232C DCE port.

1000-04 RS-232C Cable Information

Information about the included DTE to DCE cable and gender changer.

Sample Program

Warranty Information

Related product manuals