Installation Manual
7000 Apple Tree Avenue
Bergen, NY 14416
ph: 800-543-2550
fax: 585-494-1839
www.libertypumps.com
Copyright © Liberty Pumps, Inc. 2018
All rights reserved.
PUMPS
7225000I
Simplex Sewage/Grinder Systems
Models
Pro370-Series
Sewage System
Pro380-Series
Sewage System
ProVore
®
380-Series
Grinder System
Pro380-Series
Sewage System
ProVore
®
380-Series
Grinder System
700-Series
Sewage System
ProVore
®
700-Series
Grinder System
Vertical Discharge
21”D x 30”H
41 Gallon System
Vertical Discharge
24”D x 24”H
41 Gallon System
Side Discharge
24”D x 24”H
41 Gallon System
Vertical Discharge
24”D x 36”H
70 Gallon System
«Indoor Installation
Only»

Questions and Answers

  • J
    Jeremy AyalaJul 25, 2025
    What to do if my Liberty Pumps Pro380 Water Pump will not run?
    • P
      Phillip ClarkJul 25, 2025
      First, ensure the unit is securely plugged in. Then, have an electrician inspect the wiring for proper connections, voltage, and capacity. Also, check if the switch is obstructed, preventing it from turning on, and ensure the liquid level is sufficient to activate the switch. If these steps don't resolve the issue, the switch may be defective and require replacement.
  • B
    Benjamin WallaceJul 31, 2025
    Why does my Liberty Pumps Water Pump run or hum, but not pump?
    • S
      Stacey ScottAug 1, 2025
      This can occur if the discharge line is blocked by foreign material, including ice in cold areas. The check valve might be stuck closed or installed backward. Ensure that any gate or ball valves are open. The pump's total head (lift height) might exceed its capability, requiring either lower routing or a larger pump. Lastly, the pump impeller could be jammed or the volute casing plugged, requiring cleaning.
  • G
    greenejoseAug 6, 2025
    What to do if my Liberty Pumps Pro380 will not turn off?
    • C
      Crystal MitchellAug 6, 2025
      If your pump won't turn off, the switch may be obstructed, preventing it from moving to the 'off' position. Ensure there's adequate clearance for free operation. If the switch operates freely, it may be defective and need replacement.
  • M
    Maria BishopAug 12, 2025
    How to fix a Liberty Pumps Pro380 that operates noisily?
    • S
      Shannon HurstAug 12, 2025
      Noisy operation can be due to several factors. There might be foreign objects in the impeller cavity, which requires removing and cleaning the pump. A broken impeller or worn bearings could also be the cause, requiring you to consult Liberty Pumps for impeller replacement or return the pump for repair. Also, check if the piping attachments to the building are too rigid; replacing a section with a rubber hose might help.
  • A
    Austin AndersonAug 19, 2025
    Why does my Liberty Pumps Water Pump run periodically when fixtures are not in use?
    • J
      Jenna HigginsAug 19, 2025
      This issue may arise if the check valve is missing, stuck open, or leaking. Remove the check valve and inspect it for proper installation and free movement. Another possibility is that fixtures are leaking, so repair any leaking fixtures to stop the pump from running unnecessarily.

Summary

Introduction

Understanding Pump System Basics

Provides foundational information on ProVore, Pro-Series, and 700-Series pump systems prior to installation.

Basin Dimensions and Specifications

370-Series Basin Dimensions

Details the physical measurements and specifications for 370-Series basins.

380-Series Vertical Discharge Basin Dimensions

Outlines the physical measurements for 380-Series vertical discharge basins.

Pump Cover Specifications

370-Series Cover Details

Explains the components and layout of the 370-Series pump cover.

380-Series Vertical Discharge Cover Details

Illustrates the features and arrangement of the 380-Series vertical discharge pump cover.

380-Series Side Discharge Cover Details

Describes the specific design elements of the 380-Series side discharge pump cover.

Installation and Connections Guide

In-Ground Basin Installation Procedures

Step-by-step guide for excavating, backfilling, and connecting basins for in-ground systems.

Venting Requirements and Installation

Details specifications and methods for proper system venting.

Quick Tree System and Access Cover

Quick Tree Float Settings

Explains float placement and tether length adjustments for Pro370/Pro380-Series systems.

700-Series Pump Access Cover

700-Series Cover Access and Float Location

Describes the access cover and float arrangement for 700-Series systems.

Electrical Service and Operation

Manual Pump Operation and Wiring

Guides on temporary manual operation and direct wiring for automatic pumps.

Supplemental Installation Procedures

10 Stack Test Basin Installation (XL-Series)

Specific instructions for installing XL-Series basins to meet 10' stack test requirements.

XL-Series System Types

Overview of available XL-Series basin configurations and kits.

XL-Series Basin Installation

Details on basin installation for XL-Series systems, including riser requirements.

Installing XL-Series Pump and Cover

Steps for fitting pumps and securing covers for XL-Series basin assemblies.

Maintenance and Troubleshooting

Troubleshooting Common Pump Issues

Provides a matrix of common problems, their causes, and corrective actions for pump systems.

Product Warranty Information

Liberty Pumps Limited Warranty Terms

Outlines the terms, conditions, and limitations of the Liberty Pumps wholesale product warranty.