* LEAVE FOR HOMEOWNER
NOTE: Due to ongoing research and product development, specifications,
ratings and dimensions are subject to change without notice.
OPERATION AND
INSTALLATION MANUAL
®
CLEAN • FRESH • AIR
NOTE: ALTHOUGH SOME MODELS
DIFFER IN OPERATION, THE BASIC
STEPS ARE SIMILAR.
CAUTION
Before installation, careful consideration must be given to
how the system will operate if connected to any other piece
of mechanical equipment, i.e. a forced air furnace or air
handler, operating at a higher static. After
installation, the
compatibility
of the two pieces of equipment must be
confirmed, by measuring the airflow’s of the Heat/Energy
Recovery Ventilator (HRV/ERV), by using the balancing
procedure in this manual.
It is always important to assess how the operation of any
HRV/ERV may interact with vented combustion equipment
(ie. Gas Furnaces, Oil Furnaces, Wood Stoves, etc.).
NEVER install an HRV/ERV in a situation where its normal
operation, lack of operation or partial failure may result
in the backdrafting or improper functioning of vented
combustion equipment!!!
TI-72C-NE
0105
Installing Contractor
Telephone / Contact
Serial Number
Installation Date Model
TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION
For Models:
500DCS ControlAir 15
850FD/DDAnalog Controls
700FD/DD Analog Controls
1200FD/DD Analog Controls
500ERV ControlAir 15
700ERV Analog Controls
1200ERV Analog Controls

Questions and Answers

  • A
    Anthony GarciaAug 12, 2025
    Why do Lifebreath Air Handlers have poor airflow?
    • H
      howardgreeneAug 12, 2025
      Poor airflow in Lifebreath Air Handlers can stem from several causes: * A plugged 1/4 in. (6mm) mesh on the outside hood. Solution: Clean exterior hoods or vents. * Filters being plugged. Solution: Remove and clean the filter. * An obstructed core. Solution: Remove and clean the core. * Closed or blocked house grilles. Solution: Check and open the grilles. * Closed dampers (if installed). Solution: Open and adjust the dampers. * Poor power supply at the site. Solution: Have an electrician check the supply voltage. * Ductwork restricting the HRV. Solution: Check the duct installation. * Improper speed control setting. Solution: Increase the speed of the HRV. * Improperly balanced HRV airflow. Solution: Have a contractor balance the HRV.
  • J
    Jennifer WilsonAug 20, 2025
    Why is supply air cold from my Lifebreath Air Handler?
    • A
      Andrew BallAug 20, 2025
      Cold supply air from Lifebreath Air Handlers can be due to: * Poor location of supply grilles, causing airflow to irritate occupants. Solution: Locate grilles high on walls or under baseboards; install ceiling-mounted diffusers or grilles to avoid direct airflow on occupants. * Extremely cold outdoor temperature. Solution: Turn down the HRV supply speed. A small duct heater (1 kW) could be used to temper the supply air. * Placement of furniture or closed doors restricting air movement. Solution: If supply air is ducted into the furnace return, the furnace fan may need to run continuously to distribute ventilation air comfortably.
  • E
    Elizabeth SandovalAug 25, 2025
    What to do if my Lifebreath Air Handler HRV and/or ducts are frosting up?
    • C
      Carmen MooreAug 25, 2025
      If your Lifebreath Air Handler HRV and/or ducts are frosting up: * HRV airflows may be improperly balanced. Note: minimal frost build-up is expected on cores before unit initiates defrost cycle functions. * There may be a malfunction of the HRV defrost system. Have an HVAC contractor balance the HRV.
  • M
    Michael BrownAug 27, 2025
    What to do if my Lifebreath Air Handlers dehumidistat is not operating?
    • M
      Melissa ReevesAug 27, 2025
      If the dehumidistat on your Lifebreath Air Handlers isn't working, check these potential issues: * Outdoor temperature is above 15°C (59°F): The dehumidistat is functioning normally (see Auto Dehumidistat Disable in this manual). * Improper low voltage connection: Verify the correct terminals are used. * External low voltage is shorted out by a staple or nail: Check external wiring for shorts. * Dehumidistat is set to OFF: Set the dehumidistat to the desired setting.
  • C
    cwattsAug 31, 2025
    What causes condensation or ice buildup in the insulated duct of my Lifebreath Air Handler?
    • I
      Isaac OrtizAug 31, 2025
      Condensation or ice buildup in the insulated duct of your Lifebreath Air Handler could be due to: * An incomplete vapor barrier around the insulated duct. Solution: Tape and seal all joints. * A hole or tear in the outer duct covering. Solution: Tape any holes or tears in the outer duct covering, ensuring the vapor barrier is completely sealed.
  • R
    richardrobinsonSep 3, 2025
    What to do if my Lifebreath Air Handler has excess water in the bottom?
    • J
      Jason KennedySep 3, 2025
      If there's excessive water at the bottom of your Lifebreath Air Handler, check: * Drain pans for obstructions in the drain line. * For kinks in the drain line, indicating improper connection of the HRV’s drain lines.
  • M
    Mr. Robert BradleySep 7, 2025
    Why are humidity levels too low with Lifebreath Air Handlers?
    • L
      Leslie JacksonSep 7, 2025
      Low humidity levels with Lifebreath Air Handlers can result from: * The blower speed of the HRV being too high. Suggested solution: Decrease HRV blower speed. * Lifestyle of occupants. Suggested solution: Humidity may have to be added using humidifiers. * HRV airflows may be improperly balanced. Suggested solution: Have contractor balance HRV airflows.
  • C
    Carlos NealNov 15, 2025
    What to do if humidity levels are too high with Lifebreath Air Handlers?
    • B
      Brandon BuchananNov 15, 2025
      If you're experiencing high humidity levels and condensation with your Lifebreath Air Handlers, consider these factors: * Dehumidistat is set too high: Lower the dehumidistat. * HRV is not sized to handle a hot tub, indoor pool etc: Cover pools and hot tubs when not in use. * Lifestyle of the occupants: Avoid drying clothes indoors, storing wood inside, and venting the clothes dryer inside. Move firewood outside. * Moisture coming into the home from an unvented or unheated crawl space: Vent the crawl space and place a vapor barrier on the floor. * Moisture remaining in washroom and kitchen areas: Ensure ducts from the washroom are sized to effectively remove moist air; use a bathroom fan for short periods to remove additional moisture. * Condensation forming in spring and fall...