Performance and technical data
Minimum operating temperature >0
o
C (32
o
F)
Maximum operating temperature 50
o
C (122
o
F)
Minimum storage temperature -10
o
C* (14
o
F)
Maximum storage temperature 50
o
C (122
o
F)
Initial flow rate 2L/min@0.5 Bar¹
Cartridge service rating 10,000 litres (2650 US gallons)
MWCO 200KDa – on dextranes
Bacteria retention >99.999995 % (log 7.5)
2
Virus retention >99.999 % (log5)
3
Chemical reduction Optional Activated Carbon Disc available to
reduce chemical residues, inc; pesticides,
endocrine disrupting compounds, medical
residues and heavy metals
LIFESAVER
®
jerrycan US compliance EPA - US National Primary Drinking Water
Regulations under the Safe Drinking Water
Act 93-523
LIFESAVER
®
jerrycan UK compliance Water Supply (Water Quality) Regulations 2000
LIFESAVER
®
jerrycan EU compliance European Drinking Water Directive Council
Directive 98/83/EC
LIFESAVER
®
jerrycan WHO compliance Guidelines for Drinking-water Quality First
Addendum 3rd Edition
Membrane approvals/compliances CE, EPA, NSF, WHO, WRAS, DVGW, KIWA,
KTW, LSHTM
Dry weight of jerrycan inc. cartridge 3.9kg (approx. 137 oz)
Jerrycan storage capacity 18.5L (39.09 US pints, 625.44 US oz)
1
Flow rates and capacity depend on the quality of the feed water
2
Tested by London School of Hygiene & Tropical Medicine using
Escherichia coli NCTC 10418 in accordance with the Protocol
for Microbiological Water Purifiers in accordance with US
Environmental Protection Agency (EPA) guidelines.
3
Tested by London School of Hygiene & Tropical Medicine using Poliovirus Type 1
(Sabin vaccine strain) in accordance with the Protocol for Microbiological Water
Purifiers in accordance with US Environmental Protection Agency (EPA) guidelines.
* After first use the product should be protected against freezing
T
e
s
t
e
d
&
C
e
r
t
i
f
i
e
d
b
y