1 SET DMX ADDR?
If you intend to use DMX512 as the control protocol, you must set a start address.
Press 4.
/to select the attribute to change and press 4.
11 START ADDRS?
111 START [001]
Default = 001.
/to desired start channel and press 4. STORED OK
12 AUX ADDRS?
The auxiliary channel allows control of the fan operation; see page 2. However, if the input in menu 51
has been set to WP6+CONT, the seventh channel no longer controls the fan but is used to move between
WP6 control and DMX control as described on page 5.
121 AUXdmx [nnn]
Default = off
/to desired start channel and press 4. STORED OK
2 SET CHANNELS?
You may set the following attributes for each channel. Channel numbers are always expressed as channels 1-6 (or in
some cases A for All channels) of this Dimmer pack and do not refer to DMX addresses.
Press 4.
/to select the attribute to change and press 4.
21 SET PREHEAT?
Set preheats to enhance lamp performance. Set a level where the lamp filaments just glow.
211 CHANNEL [n]
/to select channel (or All option [A]) and press 4.
2111 LEVEL [000]
Default = 0.
/to desired level and press 4. STORED OK
22 SET MAX OUT?
You may set the maximum output level for each channel. Thus if a channel is set to 50%, full slider travel on
the control desk will be needed to bring the channel to 50%.
221 CHANNEL [n]
/to select channel (or All option [A]) and press 4.
2211 LEVEL [nnn]
Default = 255 (full)
/to desired level and press 4. STORED OK
23 SET CURVES?
Choose from: Linear, Square, Switch. Square law curve will provide a more accurate relationship between
lamp brightness and control desk slider position, when using incandescent lamps.
Note that switch is specifically not a curve! It allows a switch only between full-on (at DMX120) and full-off (at
DMX 40) and is used where the connected load may be damaged if dimmed.
231 CHANNEL [n]
/to select channel (or All option [A]) and press 4.
2311 CURVE [LIN]
Default = Linear
/to select curve and press 4. STORED OK