Code
Function
Range
Note
Factory Default
P0
High temperature warning point
0 ~ 75
38.7
P1
Exhaustion temperature up limit
0 ~ 75
Start exhausting for cooling
38.2
P2
Exhaustion temperature low limit
0 ~ 75
Stop cooling exhausting
38.0
P3
Main temperature up limit
0 ~ 75
Main heater stops heating
38.0
P4
Main temperature low limit
0 ~ 75
Main heater starts heating
37.9
P5
Aux temperature up limit
0 ~ 75
Aux heater stops heating
37.7
P6
Aux temperature low limit
0 ~ 75
Aux heater starts heating
37.5
P7
Low temperature warning point
0 ~ 75
37.2
P8
High humidity warning point
0 ~ 99%
70
P9
Humidity up limit
0 ~ 99%
Humidify load stops humidifying
60
Pb
Humidity low limit
0 ~ 99%
Humidify load starts humidifying
55
Pc
Exhaustion humidity up limit
0 ~ 99%
Start ventilation for de-humidifying
65
Pd
Exhaustion humidity low limit
0 ~ 99%
Stop de-humidifying ventilation
60
PE
Over wet exhaustion protection
0/1
0: disable; 1: enable
0
PP
Low humidity warning point
0 ~ 99%
50
Set function control parameter
PressSetandsimultaneously to enter into function control parameter setting status.
PressEnterto select parameter.
SV window displays the selection from “***” + “F1” to “***” + “FF”.
Pressorto set the value of the parameter (Keeping the key depressed can fast set).
KeepingEnterdepressed for 2 seconds will exit setting status, the settings will be saved.
The setting status will exit without saving, if there is no key operation for 15 seconds.
Function control parameter code table:
Code
Function
Range
Factory Default
F1
Egg turn period
1 ~ 999 min
90
F2
Egg turn time
0 ~ 999 sec
180
F3
Egg turn times
0 ~ 999 times
0
F4
Air exhausting period
1 ~ 999 min
120
F5
Air exhausting time
0 ~ 999 sec
30
F6
Temperature calibration
-9.9 ~ 9.9
0.0
F7
Humidity calibration
-20 ~ 20%
0
F8
Illumination period
1 ~ 999 min
90
F9
Illumination time
0 ~ 999 min
0
FF
Incubated days
0 ~ 99 day
0
Check Incubated Days and Egg Turned Counter
PressEnterandsimultaneously, SV window displaysincubated days, FF“days” + “t1” for 2 seconds.
PressEnterandsimultaneously, SV window displays egg-turned-counter “times” + “t2” for 2 seconds.
Control and Operation
On/off operation
KeepLamp - I/Odepressed for 2 seconds, controller turns on or off.
Illumination operation
Manual on/off: PressLamp - I/O, lamp turns on or off.
Timer on/off: For everyIllumination period, F8, lamp will be on forIllumination time, F9.
Temperature control
Main heater: When room temperatureMain temperature low limit, P4, the main heater will be on.
When room temperatureMain temperature up limit, P3, the main heater will be off.
Aux. heater: When room temperatureAux temperature low limit, P6, the aux. heater will be on.
When room temperatureAux temperature up limit, P5, the aux. heater will be off.
Temperature and humidity control parameter code table:

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lilytech ZL-7918A and is the answer not in the manual?

Lilytech ZL-7918A Specifications

General IconGeneral
BrandLilytech
ModelZL-7918A
CategoryTemperature Controller
LanguageEnglish

Related product manuals