Fan: When room temperatureExhaustion temperature up limit, P1, the fan will be on.
When room temperatureExhaustion temperature low limit, P2, the fan will be off.
Humidity control
Humidifier: When room humidityHumidity low limit, Pb, humidity output will be on.
When room humidityHumidity up limit, P9, humidity output will be off.
Fan: When PE = 1, when room humidity Exhaustion humidity up limit, Pc, the fan will be on.
When room humidity Exhaustion humidity low limit, Pd, the fan will be off.
When PE = 0, no protecting exhaustion when over wet.
Egg Turn control
For everyEgg turn period, F1, egg turn output will be on forEgg turn time, F2.
Egg turn left output and right output will be on alternatively.
1 left turn + 1 right turn = 1 egg-turn. Every egg-turn, egg-turned-counter increases 1.
When egg-turned-counter reachesEgg turn times, F3, there will be no egg turn, and LED “UP” and “DOWN” will
be blinking.
Fast check the egg-turned-counter: see paragraph at page 2: Check Incubated Days and Egg Turned Counter
Keepingdepressed for 2 seconds can start to force left turning.
Keepingdepressed for 2 seconds can start to force right turning.
Attention: When power supplied, or when controller offline, the egg-turned-counter will be reset to zero.
Exhaustion Timer control
For everyAir exhausting period, F4, the fan will be on forAir exhausting time, F5.
Alarm control
When room temperatureHigh temperature warning point, P0, buzzer alarms, room temperature display blinks.
When room temperatureLow temperature warning point, P7, buzzer alarms, room temperature display blinks.
When room humidityHigh humidity warning point, P8, buzzer alarms, room humidity display blinks.
When room humidityLow humidity warning point, PP, buzzer alarms, room humidity display blinks.
The buzzer alarming can be stopped and restored by pressingEnterkey.
Temperature and humidity calibration
The sensors have tolerance. They can reach to absolute 0.1 and 1% RH accuracy by calibration.
Room temperature can be calibrated by settingTemperature calibration, F6.
Room humidity can be calibrated by settingHumidity calibration, F7.
Incubated days
Incubated days, FFrecords the incubated days.
Fast checkIncubated days, FF: see paragraph at page 2: Check Incubated Days and Egg Turned Counter
Incubated days, FFis saved even after power supply loses, and it is not cleared after system On/Off.
To make use of the data, it is necessary to clear the record before starting a new batch incubation.
When it reaches to 99, it will not increase any more, and will stay at 99.
Restore to factory setting
Keep
and
depressed simultaneously for 2 seconds, SV window displays “000” + “00”
buzzer beeps, then
release the keys’ pressing, the controller will restore to factory default settings.