Do you have a question about the LIMIT 94 and is the answer not in the manual?
Type | Infrared Thermometer |
---|---|
Response Time | 500ms |
Distance to Spot Ratio | 12:1 |
Laser Pointer | Yes |
Display | LCD with backlight |
Power | 9V Battery |
Measurement Time | 0.5 seconds |
Memory | No |
Waterproof | No |
Accuracy | ±1.5°C or ±1.5% |
Emissivity | Adjustable from 0.1 to 1.0 |
Resolution | 0.1°C |
Battery | 9V |
Auto Power Off | Yes |
Describes the LIMIT 94 IR thermometer's function and design for measuring surface temperature.
Advises against looking directly into the laser beam to prevent eye injury.
Lists key attributes of the IR thermometer, including dual lasers, unit selection, and data hold.
Details technical parameters like measurement range, accuracy, D:S ratio, and laser properties.
Identifies key components and controls of the IR thermometer with numbered labels.
Explains the meaning of various icons and symbols shown on the thermometer's LCD screen.
Provides step-by-step instructions for basic functions like power on/off, manual measurement, and laser setup.
Details how to switch between displaying maximum and minimum temperature readings.
Guides users on how to locate thermal anomalies by sweeping the measurement area.
Explains the Distance to Spot ratio (12:1) and its impact on measurement accuracy based on distance.
Advises on ensuring the target is larger than the laser spots for accurate measurement.
Explains emissivity and provides a table of emissivity values for various materials.
Provides instructions for opening the battery cover and installing or replacing the 9V battery.