1
Limit 94
OPERATION MANUAL
English
Overview
LIMIT 94 professional non-contact infrared thermometer can determine surface temperature through
measuring infrared energy radiated by the target surface. Compact and lightweight design easy to carry.
Warning:
To avoid eyes injury, do not look directly in to the laser beam.
2
LASER
!
Features
• Dual laser beams
• User selectable ºC or ºF
• Compact and ergonomic design
• Distance to spot ratio 12:1
• Automatic Data Hold
• Inverted display
• MAX/MIN function
Specications Limit 94
IR measurement range: -50°C ~ 380ºC (-58°F ~ 716°F)
IR accuracy: -50°C ~ 20°C (-58°F ~ 68°F): ±2.5°C (4.5°F)
20°C ~ 380°C (68°F ~716°F): ±1.0% ±1.0°C (1.8°F)
D:S ratio: 12:1
Emissivity: 0.95
Response time: 150 ms
Spectral response: 8 um ~ 14 um
Temperature resolution: 0.1 °C (0.1°F)
IR repeatability: -50°C ~ 20°C (-58°F ~ 68°F): ±1.3°C (2.3°F)
20°C ~ 380°C (68°F ~ 716°F): ±0.5% ±0.5°C
Laser beam qty: 2
Laser type: CLASS II
Laser wavelength: 630 nm ~ 670 nm
Laser power: <1 mW
Battery type: 9 V (1604A, 6LR61)
Battery life: ≤ 10 h
Product size: 131 mm × 96 mm × 35 mm
Weight: 130 g
Operating temperature: 0°C ~ 50°C (32°F ~ 122°F)
Operating humidity: < 90% RH (non-condensing)
Operating altitude: 2000 m
Storage altitude: 12000 m
Protection level: IP4x
Positions
1. Measurement trigger
2. Laser On / Off key
3. °C / °F and buzzer on / off button
4. Max / Min key
5. LCD display
6. Battery cover
English
GB
1
2
3