Chapter 4.7 Troubleshooting Page 13 of 13
Specifications are subject to change without prior notice
LINAK
®
SALES BACKUP
1
st
DESKLINE
®
edition rev. 2020-01-09
Error
code
Name Description Potential cause Remedy
E88 Slave 2 Connection to 2nd
slave lost OR following
messages are from 2nd
slave
[Only used in multi-
parallel system]
• Poor cable
connection to slave
box
• If followed by
another error code,
then codes being
communicated
from slave box
- Check connection to
master box, check cable
integrity
- If communicating other
error codes, see above
E89 Slave 3 Connection to 3rd
slave lost OR following
messages are from 3rd
slave
[Only used in multi-
parallel system]
• Poor cable
connection to slave
box
• If followed by
another error code,
then codes being
communicated
from slave box
- Check connection to
master box, check cable
integrity
- If communicating other
error codes, see above
E93 Desk Sensor 1
– Activation
Detected trigger from
LIN bus safety limit
switch, e.g. DS1
• DS1 was triggered - Remove any obstacles
causing the desk drive to
stop and adjust the height
again.
E94 Desk Sensor 1
– Not
Responding
LIN SLS unit (e.g. DS1)
no longer responding
• DS1 can no longer
be detected
- Check that the DS1 is
correctly mounted.
- Remove the DS1 and re-
insert it