Chapter 4.7 Troubleshooting Page 9 of 13
Specifications are subject to change without prior notice
LINAK
®
SALES BACKUP
1
st
DESKLINE
®
edition rev. 2020-01-09
Error
code
Name Description Potential cause Remedy
E35 Ch1 pulse fail Channel 1 had to many
pulse errors
• Loose/faulty cable
• Hall sensor PCB
- Check motor cable
connections and integrity
(P2)
- Replace column
- Initialise the system (P1)
E36 Ch2 pulse fail Channel 2 had to many
pulse errors
• Loose/faulty cable
• Hall sensor PCB
- Check motor cable
connections and integrity
(P2)
- Replace column
- Initialise the system (P1)
E37 Ch3 pulse fail Channel 3 had to many
pulse errors
• Loose/faulty cable
• Hall sensor PCB
- Check motor cable
connections and integrity
(P2)
- Replace column
- Initialise the system (P1)
E38 Ch4 pulse fail Channel 4 had to many
pulse errors
• Loose/faulty cable
• Hall sensor PCB
- Check motor cable
connections and integrity
(P2)
- Replace column
- Initialise the system (P1)
E41 Ch1 overload
up
Overload up occurred
on channel 1
• Column is
overloaded
• Hit obstruction
• Reached end
stop (before
initialisation at
upper end stop
occurs)
- Remove load
- Remove obstruction (P3)
- Initialise if necessary (P1)
E42 Ch2 overload
up
Overload up occurred
on channel 2
• Column is
overloaded
• Hit obstruction
• Reached end
stop (before
initialisation at
upper end stop
occurs)
- Remove load
- Remove obstruction (P3)
- Initialise if necessary (P1)
E43 Ch3 overload
up
Overload up occurred
on channel 3
• Column is
overloaded
• Hit obstruction
• Reached end
stop (before
initialisation at
upper end stop
occurs)
- Remove load
- Remove obstruction (P3)
- Initialise if necessary (P1)