IS 678 ECN 4993 Page 9 of 20
Run a small quantity of oil around the whole of the tank and allow it to drain. This
will remove any residual water and provide the tank with a coating of oil.
Close the drain valve, fit the blanking nut and fill the appliance with clean oil to the
lower level, maintain oil at the upper level during service.
A
C
D
E
F
G
B
H
J
K
Fig 3
Lighting
Ensure that the supply isolation valve is open.
Ensure the control knob (Fig 3 B) is in the ‘Off’ position (Fig 3 C). Push in and turn
anticlockwise to the pilot position (Fig 4 E) during which the piezo igniter will click to
ignite the pilot.
When the pilot is lit keep the knob depressed a further 20 seconds to establish the
pilot flame. If the pilot fails to light, return the knob to the ‘Off’ position, allow time
for the control to reset and then repeat the process.