DIAGNOSTIC MESSAGES
The control panel displays messages and information that can help with fault
diagnosis.
Before calling for service, draw off a litre of water, clear the fault code by
pressing the Fn button and turn the boiler off and on again at the mains
supply. If the fault persists call service for advice.
Message Displayed Possible cause Corrective action
Scale on level sensors
Boiler overfilling
Descale.
Check water inlet
valve
Water turned off
Inlet hose bent or blocked
Water pressure too high
or low
Drain valve open
Check water
supply and drain
valve.
Call service if fault
persists
Boil-dry / overheat
protector tripped
Temperature sensor fault
Element failed
PCB fault
Faulty / loose connection
Check
connections.
Call service if fault
persists
Temperature set too high
Temperature sensor fault
Boiler not filling
Excessive scale in tank
PCB fault
Reduce
temperature
setting and try
again.
Call service if fault
persists
Temperature sensor fault Call service