IS339 ECN3539
5
EB4F
The boiler is supplied with a bulkhead cable connector and must be fitted with
2.5mm
2
3-core cable.The supply end of the cable must be fitted with an all-
pole disconnection isolator switch with a minimum of 3mm contact separation.
For safety regulations the means of disconnection must always be accessible.
EB6F / EB6TF
The boiler is supplied with a bulkhead cable connector and must be fitted with
4mm
2
single or 3-phase cable. The supply end of the cable must be fitted with
an easily accessible all-pole disconnection isolator switch with a minimum of
3mm contact separation. For safety regulations the means of disconnection
must always be accessible.
Water supply and waste connection: all models
Connect the supplied white water inlet hose to the inlet connection point on
the base of the boiler and the other end to the mains water supply via an
accessible isolating tap with a ¾” BSP thread.
The drip tray has a large capacity but if required it can be connected to a
waste water outlet using a ½” bulkhead connector (not supplied)
If cables are required to exit at either side of the boiler the thinner section
between the moulded feet may be cut away using a junior hacksaw.