EasyManua.ls Logo

Lincat Silverlink 600 - Technical Data; Checklist of Enclosures

Lincat Silverlink 600
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IS 678 ECN 4411 Page 4 of 20
TECHNICAL DATA
J5
J10
Height (mm)
1050
1050
Width (mm)
300
600
Depth (mm)
750
750
Weight (kg)
46
75
Inlet connection
R
½
(½” BSP)
Gross heat input – Natural (kW)
12
24
Gross heat input – Propane (kW)
12
24
Gross heat input – Butane (kW)
12.5
25
Supply pressure – Natural (mbar)
20
20
Supply pressure – Propane (mbar)
37 - 50
37 - 50
Supply pressure – Butane (mbar)
30
30
Burner pressure – Natural (mbar)
20
20
Burner pressure – Propane (mbar)
37
37
Burner pressure – Butane (mbar)
28-30
28-30
Injector size – Natural (mm)
1.8
18
Injector size – Propane (mm)
1.2
1.2
Injector size – Butane (mm)
1.2
1.2
Gas consumption – Natural (m
3
h
-1
)
1.14
2.28
Gas consumption – Propane (kg h
-1
)
0.86
1.72
Gas consumption – Butane (kg h
-1
)
0.91
1.82
Maximum cooking load per basket (kg)
1.5
1.5
Tank capacity to upper level (litres)
12
12
CHECK LIST OF ENCLOSURES