6.1.15 Speed limitation no. 1 and no. 2 (options)
The LAC controller is equipped with two speed limitation inputs that will be parameterised with the
diagnostics software. In the truck standard configuration, these speed limitations are deactivated by the
controller when the terminals 1X1: 29 / 57 are permanently connected to the battery negative.
Deleting one of the negatives activates the corresponding speed limitation.
Speed limitation No. 1 => 1X1: 29
Speed limitation No. 2 => 1X1: 57