PROGRAM MODE SETTINGS
Output Mode
Reset Mode
The output below refers to the 1 Level Preset model, OUT2 of 2 Level Preset Model and to the
OUT2 in the Prewarn + 1 Level Preset Model. Default setting is Mode A.
Prescale
Incoming pulses can be prescaled to display the desired measuring unit. The prescale can be set at any value within
the range of 0.001 ~ 99.999. Default setting is 1.000.
Decimal Point Position
Decimal point position can be selected from the following settings: 0, 0.0, 0.00, 0.000. Default setting is 0.
Free Write
Any desired value can be set on the unit as the starting count value of the counter. The counter will add to or subtract from
the set value. Upon reset, the set value will be displayed. Default setting is 0.
Reset Time
Reset time sets minimum pulse time of remote reset signal. Reset time can be set to 2ms or 20ms. Default setting is 20ms.
Key Protect
There are 4 protection levels. Default setting is Level 1.
The G48 has 2 operation modes. Settings such as selection of input modes and count modes are
done in the Program Mode. Counting and Preset Values setting are done in the Run Mode.
Use the key to enter the Program Mode and the key to return to the Run Mode.
2nd level preset value
BASIC OPERATION
RUN MODE
PROGRAM MODE
1 LEVEL PRESET
TYPE
2 LEVEL PRESET
TYPE
1 LEVEL PRESET +
PREWARN TYPE
count value
preset value
count value
1st level preset value
count value
preset value
count value
count value
prewarn value
count speed input mode
count method
key protect
reset time
write
selection of decimal
point position
output mode
output time
reset mode
prescale
MODE
MODE
DISP
DISP
DISP
DISP
Output is Latched until a Reset signal is sent.
Output is Latched until Output 2 goes away.
Output is Latched until a Reset signal is sent, independent from Output 2.
Output time can be set from 10 ~ 9990ms (at 10ms steps).
ms
Output Type
Applicable Models
1 Level Preset,
OUT2 of 2 Level Preset
OUT2 of Prewarn + 1 Level Preset
PW of Prewarn + 1 Level Preset
OUT1 of 2 Level Preset
Display
Description
All Models
Hold
Hold 1
Hold 2
One Shot
Unit counts during output signal duration.
Unit does not count during output signal duration.
Unit resets at rising edge of output signal.
Unit resets at falling edge of output signal. (For One-Shot Output time only)
Unit resets at falling edge of output signal, unit display frozen during output signal duration.
(For One-Shot Output time only)
Unit resets at falling edge of output signal, unit display frozen during output signal duration.
(For One-Shot Output time only)
Unit does not count during and after output signal duration.
Auto-Reset
Overrun
(Without Auto-Reset)
Mode A
Mode B
Mode C
Mode D
Mode E
Mode F
Mode G
Lock program
Lock program & front key reset
Lock program & preset
Lock program, front key reset & preset
Protection level
can be selected
in the
Program Mode.
Level 1
Level 2
Level 3
Level 4
Prescale Formula:
Desired Display Value (per unit)
Pulse Number (per unit)
PS =
<Examples>
1. To display 1 count per 10 pulses
2. To display 1 count per 5 pulses
3. To display 2 counts per 1 pulse
: PS value = 0.1
: PS value = 0.2
: PS value = 2