EasyManua.ls Logo

Line Seiki G48 Series - User Manual

Line Seiki G48 Series
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
FRONT PANEL FEATURES
MODELS
2
3
7
1
3
6 5 4
8 9
10
KEY/P
RST PW
P S
D P
W S E
T
I
N O U T 1 2
PW
2
1
OUT
RST
KEY/P
RESET
MODE DISP
ms
Hz
6 4 3 2 15
Count display
Preset/Programming Setting display
Program item display
Output indicator
External reset input indicator
External key lock indicator
Individual digit setting keys
(Key 1 . . . . Key 6)
Reset key
Mode key
Display key
count speed
input mode / count mode
output mode
output time
prescale
decimal point position
write
reset time
key lock protection
prewarn value setting
prewarn value setting
・ Do not use this device near machines that emit strong electromagnetic
fields or objects that store static electricity.
・ Do not drop or subject this device to strong impact.
・ Do not use or store this device where it will be exposed to water or in
places with wet conditions.
・ Do not use or store this device where it can be exposed to direct
sunlight, dust, high temperature and high humidity.
・ Do not attempt to disassemble or modify this device.
・ Mount to the front panel when using this device. (Indoor use)
・ Do not use organic solvents such as thinners etc. to clean the front
panel.
・ Internal circuit may be destroyed if a voltage outside the rated
voltage is applied.
・ Basic insulation is provided between Power supply - Input circuit -
Output circuit.
(Non-insulation is provided between Power supply - Input circuit
for model G48-306)
・ When reinforced insulation (Double insulation) is required,
apply basic insulation to the external-circuit-side.)
・ Use external fuse (200mA) to the power supply input. (IEC60127)
- 1 -
各部の名称
形式
カウント表
設定値表示
設定項目表示
IN Hz
IN
OUT
OUT ms
PS
DP
W
RST ms
KEY/P
SET
PW
:書き込み
:時間選択
:キープロ
:値設定
:予報値設定
出力表示
外部入力表示
外部キープロ入力表示
桁別キー
ット
モードキー
スプレイキ
:計数速度
:入力内容設定
:出力方式設定
:出力時間設定
:プスケー
:小数点位置指定
Electronic Preset Counter Instruction Manual
Please note that misuse of this device may lead to
injury to the user or damage to the device.
Please observe all safety precautions and warnings
in this instruction manual.
LINE SEIKI CO., LTD.
Customer Service
ATTENTION
G
48 Series
G48
Series
の度は当社の電子G48買い上げ頂き
にありがとす。
の製品を安全ご使用頂ために、ご使用前に
の取扱説明書お読みにお使いい。
の説明書使用でき大切に保管い。
Thank you for purchasing our G48 Preset Counter.
Please read this instruction manual carefully before using to
ensure the correct usage of this device.
Please keep this instruction manual for future reference.
注意
取扱いを誤た場合に取扱者が傷害を負恐れの
場合や機器を損傷る恐れの場合の
注意事項記載
152-0001 東京都目黒区中央町2-37-7
37-7 Chuo-cho, 2-Chome, Meguro-ku,Tokyo 152-0001 Japan
お問い合わせ電話番号は当社ブサイご確認下さ
Please visit our company website for contact details
メールアドレス webtrade@line.co.jp
Email
ホームペー https://www.line.co.jp
Website https://www.lineseiki.com
●お問い合わせは下
ATTENTION
POUR UTILISATION EN ATMOSPHERE CONTROLEE.
FOR USE IN A CONTROLLED ENVIRONMENT.
ご使用上の注意
本器強い電磁波を出す機器の近や静電気のた物体の
使しないでください
器を落強い撃を与ださい。
本器は防水形ではんの水中や水のかか場所での使用は
くだ
本器直射日光、高温多湿の影響を受環境で使用、
しないでくさい。
本器の分解改造等を絶対に行わなださい。
本器はパネルに取付けた状態で使用い。(屋内用
フロントパをシンナなどのいように
くだ
定格以外の電圧を印加内部回路が破損す恐れが
EN/IEC規格対応上のご注意
電源-入力-出力間は基礎絶縁G48-306の電源-入力間は非絶縁)
強化絶縁二重絶縁)確保すためには外部回路側で基礎絶縁を確保
くだ
電源入力部にIEC60127 ヒュ (200mA)を接続ださい。
ATTENTION
Conformance to EN/IEC standards
6
100 mm
64 mm
Contact / Open collector /
Voltage input (Selectable)
1段 1 level preset
1段 1 level preset
標準サ
短胴サ
AC100 - 240V
DC12 - 24V
1 + 予報設定
1 level preset + prewarn
2
2 level preset
G48-305
G48-315
G48-325
G48-306
接点/
ープンコレク/
電圧入力 (選択可)
本体長/Body length
桁数/Digit
形式 / Models 設定段数/Preset
電源/Power source
入力 / Input
電子取扱説明書

Other manuals for Line Seiki G48 Series

Question and Answer IconNeed help?

Do you have a question about the Line Seiki G48 Series and is the answer not in the manual?

Line Seiki G48 Series Specifications

General IconGeneral
BrandLine Seiki
ModelG48 Series
CategoryController
LanguageEnglish

Summary

General Safety and Precautions

Usage Precautions

Notes on safe operation, avoiding strong electromagnetic fields, impacts, water, and direct sunlight.

EN;IEC Standards Compliance

Information on insulation, reinforced insulation, and required external fuses for EN/IEC standards.

Front Panel Overview

Front Panel Component Descriptions

Detailed descriptions of each component on the front panel, including displays and keys.

Basic Operation

Operation and Program Modes

Explanation of the two modes: Run Mode for counting/preset and Program Mode for settings.

How to Program Preset Value

Step-by-step guide on how to change preset values, including examples.

Programming Settings Details

Details on setting count speed, input mode, count mode, and output mode.

Configuration Settings

Output Time and Operation Modes

Configures output timing options (Hold, One Shot) and the 7 operation modes (A-G).

Prescale and Decimal Point Settings

Setting the prescale value and decimal point position for display customization.

Initial Value, Reset Time, and Key Lock

Configuring initial value, reset time, and key protection levels for enhanced control.

Program Mode Operation Guide

Program Item Selection and Setting

Guide to selecting program items like Count Speed, Input Mode, Output Mode, and setting their values.

Specific Program Settings Overview

Detailed settings for Prescale, Decimal Point, Write, Reset Time, and Key Lock within Program Mode.

Wiring and Terminal Connections

Power Source and Input Wiring

Wiring diagrams for power supply and various input signal types (Contact, Open Collector, Voltage).

Output, Key Lock, and Count Disable Wiring

Connection details for output terminals, key lock, and input inhibition for counting.

Operation Mode and Output Mode Mapping (Part 1)

2-Level Preset Model Operations

Explains output operations for 2-level preset models with modes A, B, C, D, E.

1-Level Preset + Prewarn Model Operations

Details output behavior for 1-level preset + prewarn models with modes A, B, C, D, E.

Operation Mode and Output Mode Mapping (Part 2)

Modes F & G with 2-Level Preset Model

Details output operations for modes F and G with 2-level preset settings.

Modes A, B, C with 1-Level Preset + Prewarn Model

Describes output operations for modes A, B, C in 1-level preset + prewarn models.

Product Specifications Summary

General Technical Specifications

Comprehensive list of technical specs like model, display, input/output, speed, and ranges.

Electrical, Environmental, and Physical Specs

Details on power, operating conditions, ratings, compliance, weight, and dimensions.