Black 0006
Black0006
FACTORY DEFAULTS
MASTER PROGRAMMING CODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123456
ENTRY CODE LENGTH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 DIGITS
REQUEST-TO-ENTER OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RELAY #1
ALARM SHUNT OUTPUT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISABLED
FORCED ENTRY OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OUTPUT #3
DOOR AJAR OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OUTPUT #4
RELAY #1 ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SECONDS
RELAY #2 ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SECONDS
SOLID STATE OUTPUT #3 ON TIME. . . . . . . . . . . . . . . . . . . . . . . . . 2 SECONDS
SOLID STATE OUTPUT #4 ON TIME. . . . . . . . . . . . . . . . . . . . . . . . . 2 SECONDS
DOOR SENSE/INHIBIT INPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . DOOR SENSE
KEYPAD LOCKOUT OUTPUT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISABLED
KEYPAD ACTIVE OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISABLED
BEEPER SOUNDS WHEN KEY PRESSED . . . . . . . . . . . . . . . . . . . . . . . . . . . . YES
BEEPER SOUNDS DURING RELAY #1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO
BEEPER SOUNDS DURING RELAY #2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO
BEEPER SOUNDS DURING OUTPUT #3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO
BEEPER SOUNDS DURING OUTPUT #4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO
KEYPAD LOCKOUT COUNT. . . . . . . . . . . . . . . . . . . . 3 TRIES BEFORE LOCKOUT
ANTI-PASSBACK TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO ANTI-PASSBACK
BASIC PROGRAMMING
When the AccessKey is in programming mode, both LEDs
will turn off until programming begins. After a programming
option number is entered the yellow LED will blink. This
indicates that the AccessKey is ready to accept the new
programming data. After the new data entry is complete,
the green LED will light while the data is being stored. The
red LED will light if any programming data is entered
incorrectly, and the command will have to be fully re-entered.
Entering Programming Mode
The 6-digit Master Programming Code (default = 123456)
is used to enter Programming Mode.
Press:
#
9
#
Master Code
Master Code = the current 6-digit Master Programming Code
Exiting Programming Mode
Press:
*
*
#
The red LED will light when Programming Mode is exited.
NOTE: The Accesskey will automatically exit
Programming Mode after two minutes of inactivity.
Re-entering a Command After a Mistake
If the red LED lights, indicating an incorrect entry, or a
wrong key is pressed during programming, to clear the
keypad and re-enter the command:
Press:
*
9
#
Setting Entry Code Length Default: 4 digits
Press: 0 3
#
Length
#
Length = 1 - 6 for entry code length
NOTE: If the Entry Code Length is going to be
changed from the factory default of four digits, make
this change first, before programming any entry
codes.
Adding a New Entry Code
Press: 0 1
#
Code
#
Code
#
Relay
#
Code = The new entry code:
1-999999, depending on code length
Relay = Relay output entry code will activate:
1 = Relay #1 2 = Relay #2
3 = Both Relays
The yellow LED will flash quickly while the AccessKey
searches its memory for available space and duplicate
entries. The green LED will light when the new code is
stored.
If the new entry code chosen is already being used for
another entry code, the red LED will light. A new unique
code needs to be entered.
NOTE: Leading zeros (zeros before the code
number, i.e. 0001) do not need to be entered when
programming a new entry code. The AccessKey will
internally add any zeros to fill all digits determined
by the entry code length setting. Leading zeros will
have to be entered by the user when entering their
code to gain access.
Erasing a Single Entry Code
Press: 0 2
#
Code
#
Code
#
Code = The entry code to delete.
The yellow LED will flash quickly while the AccessKey
searches its memory for the code to erase. The green LED
will light when the code is erased.
Erasing All Entry Codes
# WARNING: Performing this command will
remove
all entry codes from the memory.
Press: 9 7
#
0 0 0 0 0 0
#
0 0 0 0 0 0
#
NOTE: The green LED will light while the memory is
being erased. This may take up to 15 seconds.
Changing the 6-Digit Master Programming Code
Press: 9 8
#
Master Code
#
Master Code
#
Master Code = The new 6-digit Master Programming Code
New master code: _____________________
6