153Programming mode
14
3Programming mode
Function Parameter Entry Inputs
code no.
Exclusion area 41 1…5 #
Entry is deleted.
Release area 42 1…5
No.
max. 6
figures
#
Entry is stored.
Release area 42 1…5 #
Entry is deleted.
Factory setting: No entry in exclusion area or release area.
The blacklist monitors the selected telephone numbers for the assigned
subscribers. If a blacklisted telephone number is dialled, the subscriber
hears a busy tone. The blacklist is divided into the exclusion area and the
release area. The release area defines exceptions within the blacklist.
Depending on the area, 5 entries can each be made, consisting of 6
figures each. If a subscriber has the authorisation to make international
calls, none of the phone or fax numbers they dial starting with 00 will be
checked by the blacklist.
Programming example:
The following subscribers will be monitored: 3, 4, 6
The monitored subscribers may not make any international calls;
exception: Calls may be made to Greece and Denmark.
No 0190 telephone numbers may be dialled, except: 019012
Procedure:
1) Activate programming mode
2) Enter
40 31#4041#4061#
3) Enter
41 1 00 # 41 2 0190 #
4) Enter
42 1 0034 # 42 2 0045 #
42 3 019012 #
5) Close programming mode
3.2.14 International/national authorisation
Function Parameter Mob. no. Inputs
code
International/national 43 1…8 0#
The handset has the authorisation to set up both international (00) and
national (0) calls.
International/national 43 1…8 1#
The handset does not have any authorisation to set up international calls.
Only national calls can be made.
International/national 43 1…8 2#
The handset does not have any authorisation to set up international or
national calls.
Factory setting: 0
3.2.15 Providers
Function Parameter Prefix Inputs
code
Provider setting 45 xxxxxxxxxx #
(max. 10 figures)
Depending on the setting for parameter 46, the stored prefix is dialled for
any external call.
Factory setting: No prefix stored.