Rev: 08.24.21 Page 3 CCD-0004349
Resources Required
Phillips screwdriver
Adjustable wrenches
Flashlight
Safety glasses
Installation
With Metal Collar
1. Unscrew the metal collar with the two screws from the faucet base and set aside (Fig. 1A).
2. Remove the metal washer (Fig. 1B) from the base and set aside.
Note: Leave black rubber washer (Fig. 1C) on faucet.
3. Place the faucet supply lines through the mounting hole on the deck, making sure the black rubber
washer and faucet base are seated firmly on the deck of the sink (Fig. 2A).
4. Position the faucet base so the handle is to the right side of the faucet base (Fig. 2B).
Fig. 1
A
B
C
Fig. 2
A
B
Placing the handle in the middle may cause severe burns depending on where the faucet neck is
positioned when turning on the water.