SETTING THE ZERO POINT
LCD TO U C H PA D
• Manually run the jacks to level the unit. This is
best achieved by placing a level in the center
of the unit and leveling it both front to back
and side to side.
• Once the unit is level, turn off the touch pad.
• With the touch pad off, press and release the
“FRONT” button 5 times and then press and
release the “REAR” button 5 times.
• The touch pad will flash and beep and the
display will read “ZERO POINT CALIBRATION
ENTER to set, Power to Exit”.
• To set the current position as the zero point,
press “ENTER” button.
• LCD reads “Zero point stability check”.
• LCD display will read “Zero point set
successfully” once process is complete.
• The system will set this point as its level state
and the touch pad will turn off.
MANUAL OVERRIDE
¼” Hex Bit & Drill
Clockwise to RETRACT
Counterclockwise to EXTEND
Clockwise to OPEN
Counterclockwise to CLOSE
5/32 Hex
Wrench