6/10/2022
8
Variant Code Sticker
Notch
Motor Retention
Screw Hole
H-Column
Wiper Seal
ERROR CODES
Flashes Name Description
2 Battery Drop Out Battery capacity low enough to drop below 6 volts while running or short in switch
wiring.
3 Low Battery Voltage below 8 volts at start of run.
4 High Battery Voltage greater than 18 volts.
5 Excessive Motor Current High amperage, also indicated by 1 side of slide continually stalling.
6 Motor Short Circuit Motor or wiring to motor has shorted out.
8 Wire Short Between Controller and Motor Encoder is not providing a signal. This is usually a wiring problem.
9 Hall Power Short to Ground Power to encoder has been shorted to ground. This is usually a wiring problem.
Electronic Manual override
Mode Button: press 6x, hold on 7
th
Use switch to operate room
To exit mode: press and hold mode
button
LED Error Codes
Mode
Button
Red
LED
Green
LED
15