6/10/2022
9
MANUAL OVERRIDE
Disconnect Motor Harness
Locate controller.
Unplug both harnesses
Push or pull slide room in as desired
Keep both sides of room relatively even.
When room is completely in, plug both
motors back into the controller.
Disengage Motor
Bend back wipe seal.
Remove retention screw
Pull the motor up until disengaged
Repeat this process for both sides of the slide room.
Push or pull room back
*Travel Lock*
Unplug Both Motors
Motor Retention Screw
RE-SYNCHRONIZING
MOTORS
1. Fully extend the slide room using the switch. Keep
the switch engaged until the motors shut down on
their own.
2. Retract the room 1-2 inches.
3. Repeat steps 1 and 2 until both motors shut down
at the same time. In many cases, two or three
repetitions are necessary to re-sync the system.
4. Fully extend the slide-out and keep the switch
engaged until the motors shut down on their own.
Fully retract the slide-out, again keeping the switch
engaged until the motors shut down on their own. If
both motors shut down at the same time at full
extension and full retraction, the room is properly
synchronized. If they do not shut down at the same
time, repeat the process until they do.
17