SERVICE MANUL
Haier Front Load Washing Machine
14
Error message:Temperature sensor is not properly connected or damaged.
Troubleshooting:
Error message:The heater may be broken(dispiay at the end of a program).
Troubleshooting:
N
NTC exist open circuit. Replace it
Y
Cut off power, check the resistance of
two pins of heater element by
multimeter, is it between 27-30
?
Heater element must
be broken, please
replace it
Y
Check if NTC is connected properly
Cut off power and measure the resistance
of temperature sensor by
multimeter,is
it between 5-14k
?
Y
N
Connect NTC well
N
N
The control wire may be broken,
Otherwise the PCB must be broken;
Please replace the broken.
N
Replace PCB
Check the wire
between NTC
and PBC, are they connected well?
Connect all wires well
Disconnect the two black wires from PCB
, and measure if the resistance
between the two black wires of PCB, is
it infinite?
Y
N
Y
Replace wire
Check if overload laundry. Reduce the laundry
Y
03D Series

Other manuals for Logik L614WD13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Logik L614WD13 and is the answer not in the manual?

Logik L614WD13 Specifications

General IconGeneral
BrandLogik
ModelL614WD13
CategoryWasher/Dryer
LanguageEnglish

Related product manuals