30
Table for the Choice of the Injectors
Burner Injector Values
According To The Gas Type
LPG Natural Gas
G30/G31
28-30/37 mbar
G 20-20
mBar
Large Burner (Fast)
Injector mm 0.850 1.150
Gas Flow
(15°C and 1013mbar)
218.13 gr/h 285.70 lt/h
Power kW 3.000 3.000
Standard Burner
Injector mm 0.650 0.970
Gas Flow
(15°C and 1013mbar)
127.25 gr/h 166.66 lt/h
Power kW 1.750 1.750
Small Burner (Simmer)
Injector mm 0.500 0.720
000Gas Flow
(15°C and 1013mbar)
72.71 gr/h 95.24 lt/h
Power kW 1.000 1.000
Grill Burner
Injector mm 0.690 1.100
Gas Flow
(15°C and 1013mbar)
152.7 gr/h 209.50 lt/h
Power kW 2.100 2.200
Main Oven Burner
Injector mm 0.750 1.150
Gas Flow
(15°C and 1013mbar)
174.50 gr/h 228.60 lt/h
Power kW 2.400 2.400
GB: II2H3+ Total Power 12 kW 12.1 kW
• All intervention regarding installation maintenance and conversion of the appliance must be
fulfilled with original factory parts.
• The manufacturer declines any liability if these correct parts are not used.
LFTG60W_A12_IB_rollover.indd 30 29/03/2016 17:09