26
Ventilation Requirements
This appliance is not connected to a combustion products evacuation device. It should be installed and
connected in accordance with current installation regulations. Particular attention should be given to the relevant
requirements regarding ventilation.
The appliance should be installed in a room or space with an air supply in accordance with the latest edition
of BS5440-2. This appliance needs 2m
3
/h air per Kw input
For rooms with a volume of less than 5m
3
— permanent ventilation of 100cm
2
free area will be required.
For rooms with a volume of between 5m
3
and 10m
3
a permanent ventilation of 50cm
2
free area will be required
unless the room has a door which opens directly to the outside air in which case no permanent ventilation
is required.
For rooms with a volume greater than 10m
3
— no permanent ventilation is required.
Gas Installation
Installation and Service Regulations
Regardless of room size, all rooms containing the appliance must have direct access to the outside
air via a window that opens or equivalent.
Where there are other fuel burning appliances in the same room, the latest edition of BS 5440-2
should be consulted to determine the correct amount of free area ventilation requirements.
This cooker uses and is ready to use NATURAL GAS only and cannot be used with any other gas
without modification. This appliance is manufactured for conversion to LPG after fitting new injectors
(supplied) and making adjustments. Refer to replacement of burner injectors” section for details.
This appliance must be installed and serviced only by a suitably qualified and Gas Safe Registered
engineer, and in accordance with the current editions of the following standards and regulations or
other locally applicable regulations:
Gas Safety (Installation and Use) Regulations
Building Regulations
British Standards (BS 5440, BS 6172 and BS 6891)
Regulations for Electrical Installation (BS 7671, (Latest Edition))
Gas Installation Checks
After installation, check for gas soundness. The supply pressure can be checked at the front left
hotplate burner injector.
Logik Free Standing Twin Cavity Gas Cooker LFTG60B16/W16.indd 26Logik Free Standing Twin Cavity Gas Cooker LFTG60B16/W16.indd 26 14/12/2020 16:0714/12/2020 16:07

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Logik LFTG60W16 and is the answer not in the manual?

Logik LFTG60W16 Specifications

General IconGeneral
BrandLogik
ModelLFTG60W16
CategoryCookers
LanguageEnglish

Related product manuals