30
Table for the Choice of the Injectors
Burner Injector Values
According To The Gas Type
LPG Natural Gas
G 30/31
28-30/37 mBar
G 20
20 mBar
• All intervention regarding installation maintenance and conversion of the appliance must be
fulfilled with original factory parts.
• The manufacturer declines any liability if these correct parts are not used.
Large Burner (Fast)
Injector mm 0.850 1.150
Gas Flow
(15°C and 1013mbar)
218.13 gr/h 276.00 lt/h
Power kW 3.000 2.900
Standard Burner
Injector mm 0.650 0.970
Gas Flow
(15°C and 1013mbar)
127.25 gr/h 166.66 lt/h
Power kW 1.750 1.750
Small Burner (Simmer)
Injector mm 0.500 0.720
Gas Flow
(15°C and 1013mbar)
72.71 gr/h 95.24 lt/h
Power kW 1.000 1.000
Grill Burner
Injector mm 0.690 1.100
Gas Flow
(15°C and 1013mbar)
152.70 gr/h 209.50 lt/h
Power kW 2.100 2.200
Main Oven Burner
Injector mm 0.750 1.150
Gas Flow
(15°C and 1013mbar)
174.50 gr/h 228.60 lt/h
Power kW 2.400 2.400
Logik Free Standing Twin Cavity Gas Cooker LFTG60B16/W16.indd 30Logik Free Standing Twin Cavity Gas Cooker LFTG60B16/W16.indd 30 14/12/2020 16:0814/12/2020 16:08