5.0 There must be a current supply...
Note 1: Battery life: 1200 cycles a 80% discharge.
Longest battery life obtained, when the battery is charged
on being 80% discharged. 1 charge = 1 cycle.
Note 2: Battery life: 300 cycles at 80% discharge
= approx. 600 cycles at 50% discharge.
Note 3: Please note: Only ll up to the maximum liquid level
on a charged battery, otherwise the liquid will over ow.
See the battery instructions or contact your dealer in
case of doubts about minimum/maximum.
Dry-chargedbatteriesmustbelledwithbatteryacid
37.5% H
2
SO
4
specicgravity1.28,beforetheyare
usedforthersttime.
991222
DEKO
Vandpåfyldning 12V Seimitrack
290607
HEH
G:\Grafik\Symbol\Skilte\991222.AI
110907
HEH
Max
Min
Max
Min
35
30
Grå
Sort og grå tryk på hvid baggrund
The charging of tubular cell and semi-trak batteries
gives off gases that can be explosive:
Use of naked ames near the batteries should be avoided.•
Charging should therefore be performed in a ventilated room.•
The battery lid has to be open to ensure a good ventilation •
of the battery.
At temperatures around the freezing point, battery capacity is
reduced by 30%.
If the acid density of the battery is 1,10 and the temperature 0° C, the battery
will freeze and the capacity will be 0%.
Filling in acid solution on the battery
The battery acid is corrosive. If it should touch skin or eyes, wash •
with water and contact a doctor. Filling in acid into the battery
should be performed in a ventilated room.