LogTag UTRIX Work Instruction Manual Revision 1.07 MP Release Page 32/52
NOTES:
1. During this test, the temperature sensor reading is checked and is compared to the temperature sensor
installed in the interface. If the unit or the interface has been over-handled or the temperatures have not
been allowed to stabilise then the Verify temperature sensor reading part of the test will fail. Instruct
operators to not over handle product during test or the test fixture.
2. Use the Close button to exit program. DO NOT reset or switch off computer while it is running any test!
Failures & Corrective action.
If a test fails then a display similar to below will open describing failure.
Options are to Retry or Abort the test.
If the product will not pass the test remove it from the interface and click ABORT.
Place in separate marked container for service check. Rejected products must be clearly identified and
kept apart from accepted products
NOTE:
ALWAYS use the Close button to exit program
DO NOT reset or switch off computer while it is running any test otherwise production log files may
become corrupted!!